GC Capillary Columns
- (2)
- (3)
- (2)
- (102)
- (5)
- (15)
- (1)
- (48)
- (20)
- (1)
- (1)
- (511)
- (1)
- (1)
- (3)
- (3)
- (27)
- (2)
- (1)
- (2)
- (1)
- (85)
- (2)
- (47)
- (7)
- (1,170)
- (3)
- (26)
- (46)
- (36)
- (4)
- (542)
- (2)
- (1)
- (10)
- (1)
- (22)
- (23)
- (35)
- (111)
- (3)
- (12)
- (27)
- (754)
- (1)
- (84)
- (1)
- (697)
- (2)
- (4)
- (927)
- (1)
- (1)
- (4)
- (1)
- (2)
- (2)
- (2)
- (2)
- (160)
- (17)
- (15)
- (5)
- (34)
- (1)
- (1)
- (1)
- (28)
- (54)
- (45)
- (592)
- (1)
- (4)
- (2)
- (6)
- (9)
- (4)
- (30)
- (3)
- (3)
- (1)
- (429)
- (23)
- (1)
- (1)
- (1)
- (5)
- (3)
- (536)
- (1)
- (3)
- (2)
- (27)
- (162)
- (2)
- (31)
- (14)
- (4)
- (44)
- (2)
- (7)
- (8)
- (1)
- (211)
- (1)
- (4)
- (5)
- (81)
- (4)
- (12)
- (60)
- (3)
- (1)
- (4)
- (2)
- (1)
- (5)
- (6)
- (1)
- (2)
- (5)
- (3)
- (248)
- (8)
- (8)
- (10)
- (7)
- (47)
- (2)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (3)
- (5)
- (21)
- (1)
- (1)
- (2)
- (1)
- (1)
- (2)
- (2)
- (34)
- (4)
- (163)
- (1)
- (15)
- (1)
- (26)
- (11)
- (1)
- (3)
- (2)
- (2)
- (4)
- (33)
- (1)
- (7)
- (8)
- (4)
- (4)
- (8)
- (1)
- (2)
- (1)
- (4)
- (1)
- (8)
- (2)
- (103)
- (1)
- (1)
- (1)
- (7)
- (2)
- (1)
- (4)
- (3)
- (1)
- (39)
- (17)
- (2)
- (1)
- (1)
- (10)
- (1)
- (1)
- (38)
- (3)
- (3)
- (5)
- (2)
- (1)
- (2)
- (5)
- (23)
- (52)
- (42)
- (1)
- (49)
- (1)
- (8)
- (1)
- (4)
- (18)
- (1)
- (2)
- (82)
- (23)
- (10)
- (2)
- (51)
- (13)
- (40)
- (9)
- (12)
- (13)
- (2)
- (18)
- (11)
- (4)
- (5)
- (84)
- (12)
- (40)
- (20)
- (9)
- (11)
- (7)
- (4)
- (1)
- (3)
- (2)
- (4)
- (3)
- (10)
- (7)
- (3)
- (2)
- (2)
- (4)
- (6)
- (9)
- (5)
- (7)
- (18)
- (3)
- (6)
- (34)
- (5)
- (13)
- (12)
- (13)
- (27)
- (7)
- (27)
- (4)
- (2)
- (15)
- (3)
- (21)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (3)
- (55)
- (22)
- (10)
- (2)
- (4)
- (4)
- (1)
- (3)
- (16)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (3)
- (3)
- (2)
- (3)
- (14)
- (1)
- (10)
- (2)
- (1)
- (1)
- (3)
- (3)
- (2)
- (8)
- (9)
- (1)
- (6)
- (9)
- (1)
- (3)
- (1)
- (35)
- (14)
- (39)
- (20)
- (29)
- (1)
- (8)
- (22)
- (20)
- (5)
- (7)
- (30)
- (11)
- (7)
- (5)
- (17)
- (4)
- (9)
- (1)
- (10)
- (11)
- (3)
- (2)
- (1)
- (6)
- (9)
- (10)
- (29)
- (21)
- (13)
- (19)
- (1)
- (8)
- (5)
- (4)
- (4)
- (4)
- (1)
- (1)
- (30)
- (2)
- (3)
- (14)
- (6)
- (442)
- (42)
- (18)
- (246)
- (37)
- (9)
- (15)
- (2)
- (44)
- (80)
- (15)
- (469)
- (25)
- (32)
- (4)
- (61)
- (3)
- (2)
- (1)
- (10)
- (105)
- (196)
- (125)
- (25)
- (8)
- (2)
- (98)
- (35)
- (5)
- (6)
- (264)
Filtered Search Results
MilliporeSigma™ Supelco™ SLB™-IL76 Capillary GC Column, df 0.20 μm
Second-generation ionic liquid capillary GC column engineered with unique interaction mechanisms for distinct selectivity.
MilliporeSigma™ Supelco™ α-DEX™ 120 Capillary GC Column, df 0.25 μm
Capillary GC column is also known as open tubular column. The carrier gas flows through the central aperture and is unrestricted throughout the length of the column.
Thermo Scientific™ TracePLOT™ TG-BOND Msieve 5A GC Columns
Designed for separation of Ar/O2 and other permanent gases
MilliporeSigma™ Supelco™ Carboxen™-1010 PLOT Capillary GC Column, df 30 μm
Porous-layer open-tubular (PLOT) columns are a powerful tool used in gas chromatography for analysis of fixed gases, light hydrocarbons and volatile solvents. They are mostly preferred over traditional columns.
MilliporeSigma™ Supelco™ SPB™-Octyl Capillary GC Column, df 0.25 μm
Used for confirmational analyses of PCB-containing samples.
Thermo Scientific™ TRACE™ TR-5HT GC Columns
Thermo Scientific™ TRACE TR-5HT GC Columns feature upper temperature limits as high as 400°C.
| Stationary Phase | Trace™ TR-5 HT |
|---|---|
| For Use With (Application) | GC/MS |
| Max. Temperature (Metric) | 380/400°C |
| USP Type | G27, G36 |
| Product Line | TRACE |
| Type | GC Guard Column |
|---|---|
| Diameter (Metric) Inner | 0.53 mm |
| Quantity | 1 |
Thermo Scientific™ TRACE™ GC Columns for Dioxin and PCB Analysis
Analyze dioxins and PCBs with high-resolution GC/MS for unsurpassed performance and reproducibility.
| Diameter (Metric) | 0.25 mm |
|---|---|
| Diameter (Metric) Inner | 0.25 mm |
| For Use With (Application) | Furan (PCDF) Analysis,GC/MS for Furan (PCDF) Analysis,GC/MS for PCB Congener Analysis |
| Max. Temperature (Metric) | 360/370°C |
| USP Type | G27, G36 |
| Product Line | TRACE |
Thermo Scientific™ TraceGOLD™ TG-200MS GC Columns
Resolve compounds that phenyl and cyano phases cannot using a low-bleed GC column with an exceptionally inert phase.
| Stationary Phase | TraceGOLD™ TG-200 MS |
|---|---|
| Polarity | Mid-Polar |
| Max. Temperature (Metric) | 320/340°C |
| USP Type | G6 |
MilliporeSigma™ Supelco™ SPB™-5 Capillary GC Column, df 0.20 μm
Non-polar general purpose column provides primarily a boiling point elution order with a slight increase in selectivity, especially for aromatic compounds.
MilliporeSigma™ Supelco™ Astec™ CHIRALDEX™ B-DP Capillary GC Column, df 0.12 μm
Excellent for the analysis of aliphatic and aromatic amines
MilliporeSigma™ Supelco™ VOCOL™ Capillary GC Column, df 1.8 μm
Designed for analyses of volatile organic compounds (VOCs). Offers great retention and resolution of highly volatile compounds.
MilliporeSigma™ Supelco™ PTA-5 Capillary GC Column, df 3 μm
PTA-5 Capillary GC Column is a specially treated nonpolar capillary column, and is primarily dedicated towards amino compounds.
MilliporeSigma™ Supelco™ SPB™-608 Capillary GC Column, df 0.50 μm
Suitable for use in herbicide analyses.
MilliporeSigma™ Supelco™ SLB™-IL111 Capillary GC Column, df 0.20 μm
Great choice for separation of polarizable analytes (contain double and/or triple C-C bonds) from neutral analytes